How to maintain the pneumatic lifting column


Release time:

2023-03-25

Pneumatic lifting column as some of the main places of maintenance equipment, more and more loved by everyone. How to maintain the pneumatic lifting column? The following is a small series for everyone to answer.

Pneumatic lifting column as some of the main places of maintenance equipment, more and more loved by everyone. How to maintain the pneumatic lifting column? The following is a small series for everyone to answer.

 

气动升降柱维护


Operation: Through active remote control, access to the ground and customized programs, the bollards can be operated individually or collectively. When recycling bollards, it should be at least parallel or slightly below the ground level to ensure the barrier-free passage of motor vehicles and the normal operation of snow removal equipment. From the fully raised state to the fully recovered state, a single trip lasts no less than 3 seconds, and the recovery speed is allowed to be readjusted after the installation. From the fully recovered state to the fully raised state, a single trip lasts no less than 3 seconds, and the lifting speed is allowed to be readjusted after the installation. Cycle of Lifting Cycles-The air storage device needs to store enough air to ensure that the bollard can carry out 3 complete lifting cycles within 60 seconds.
Maintenance: basic maintenance (once/half a year):
Clean buried pits, use water or suction pumps to clean the bottom of the clean buried pit drainage facilities clean and lubricate the main sliding track.
Then check the following questions by running:
Check the air leakage of the air pipe and check the function of the head flash lamp of the lifting column.
Check the efficacy of the wireless remote control
Check the efficacy of the electric control panel
When the air pump works, the moisture and impurities in the atmosphere will be brought into the air storage tank. After a long time, sewage will be generated in the air storage tank. At this time, the drain valve should be opened for drainage.
The stability of the voltage should be maintained, and it is recommended to install a voltage stabilizer. When the working voltage of the compressor is less than 220V, it is easy to cause excessive current. At this time, the equipment protector will automatically disconnect the circuit and stop working. At this time, it is necessary to manually press the overload button on the protector to restart the equipment.
If it is not used for a long time, it should be guaranteed to lift several times a day. Through the airflow, the lubricating oil of the oil pot can enter the lifting column for lubrication and prolong the service life of the lifting column. Check the oil pot every three months. When the oil in the oil pot is almost exhausted, add ISOVG32 oil or equivalent oil.
Blowdown operation: drain water regularly according to the frequency of use and the humidity of the field air, once a week is recommended; under normal circumstances, use 1(10) to discharge sewage. Under the condition of sufficient air pressure in the air storage tank, open the blowdown valve in parallel with the blowdown outlet to carry out blowdown, and close the blowdown valve after discharge.
Note: The temperature of the compressor on the air pump is high after working for a period of time, so please do not touch it directly. Especially when it is necessary to press the emergency release valve on the back of the air pump, pay attention not to touch the surface of the compressor directly, otherwise it is easy to cause skin burning. When the air pump works, the moisture and impurities in the atmosphere will be brought into the air storage tank. After a long time, sewage will be generated in the air storage tank. At this time, the drain valve can be opened for drainage. Overload protector When the working voltage of the compressor is less than 220V, it is easy to cause excessive current. At this time, the overload protector will automatically disconnect the circuit to stop working. At this time, it is necessary to manually press the button on the overload protector to restart the equipment.
Blowdown operation: drain water regularly according to the frequency of use and the humidity of the field air, once a week is recommended; under normal circumstances, use 1(10) to discharge sewage. Under the condition of sufficient air pressure in the air storage tank, open the blowdown valve in parallel with the blowdown outlet to carry out blowdown, and close the blowdown valve after discharge.
Note: The temperature of the compressor on the air pump is high after working for a period of time, so please do not touch it directly. Especially when it is necessary to press the emergency release valve on the back of the air pump, pay attention not to touch the surface of the compressor directly, otherwise it is easy to cause skin burning.
Regular maintenance
Daily column surface cleaning, maintenance, once/day lifting column around sand and other sundries cleaning, should try to avoid sand and other sundries through the protection gap to cause the bollard stuck phenomenon, once/day sewage maintenance, once/week air filter (air filter) cleaning, replacement, once/half a year every three months to check the oil pot, when found that the oil in the oil pot is almost exhausted, can add ISOVG32 oil or equivalent oil, under normal circumstances, only need to add once a year.















 

 

 

Hebei Qi Xinlong Intelligent Technology Co., Ltd. is a research and development, design, production, sales and service in one of the anti-terrorism equipment manufacturers. Main products include: fullAutomatic lifting columnSemi-automatic lifting column, hydraulic lifting column, landscape fixed column, flap barricade, tire breaker, etc. Tel: 15531750999.

Key words:

Pneumatic Lifting Column Maintenance